TECHNICAL SPECIFICATIONS OF HOT AIR GENERATOR

1.

Model AIRPACK-400. AIRPACK-2500.

2.

Construction Rectangular Cylindrical

2

Capacity 4,00,000 Kcal/hr. 25,00,000 Kcal/hr.

3

Type Indirect Fired. Indirect Fired.

6

Outlet Temp. of Air. Upto 200 Deg.C (Max. upto 350 Deg. C) Upto 200 Deg.C (Max. upto 350 Deg. C)

5

Air Flow Rate. 9412 kg/hr (for 200 Deg.C. Outlet Temp.). 58823 kg/hr (for 200 Deg.C. Outlet Temp.).

6

Pressure Drop Across Hot Air Generator. 200-250 mm WC. 200-250 mm WC.

7

No. of Flue Gas Passes. 4 4

8

Fuel LDO/HSD. LDO/HSD.

9

Calorific Value of Fuel on GCV–
a) F.O. 10300 kcal/kg. 10300 kcal/kg.
b) LDO 10880 kcal/kg 10880 kcal/kg
c) HSD 10960 kcal/kg. 10960 kcal/kg.
Calorific Value of Fuel on NCV–
a) F.O. 9710 kcal/kg. 9710 kcal/kg.
b) LDO 10210 kcal/kg. 10210 kcal/kg.
c) HSD 10280 kcal/kg 10280 kcal/kg

10

Efficiency on NCV. 93% + 1% 93% + 1%

11

Fuel Oil Consumption (93% Eff.on NCV).
a) F.O. 44.29 kg/hr. 276.84 kg/hr.
b) LDO 42.12 kg/hr. 263.28 kg/hr.
c) HSD 41.83 kg/hr. 261.49 kg/hr.

12

Connected Load –

a) Combustion Blower and Fuel Pump.

 

3.3 kW.

 

9.7 kW.

13

Burner Modulation. ON-OFF. STEPLESS

14

Overall Dimensions (Uninsulated). –
a) Length. 2200 mm 9000 mm
b) Width 1200 mm 3600 mm
c) Height 2800 mm 4000 mm

15

Dead Weight (Approx.). 1800 kg. 11000 kg.
Note : The pressure drop across Hot Air Generator is specified as a Estimated value. The figure may very for different outlet temp.And ambient condition.